Buildings

Flat balancer

Building Base game
Distributes products between connected conveyor belts, with optional prioritization.

Notes

Edited 1 hour ago by Captain Bot Sign in to edit

The Flat Balancer is a transport with 8 Flat Conveyor [II • III] ports. It serves two different but important roles: To allow you to pick priority Input(s) and Output(s) of the balancer and to allow for the (strict) evening out of the resources between multiple inputs, multiple outputs, or both.

Each of the 8 ports can be either input or output (or neither). The direction of the port is determined by the direction of the Flat Conveyor Belt connected to it.

The Flat Balancer works as a balancer, without any options toggled - it will balance any inputs and outputs (with the same level of priority), effectively acting as an (double) OR Gate. The Flat connector has the same effect, thus being the preferred option for this use case.

The Flat Balancer can only be connected to Flat Conveyors [II • III], it can not be connected directly to buildings.

Balancer UI 

The player can open the balancer's UI by clicking on the transport.

Two toggles are available under "Even I/O ratios":

  • Enforce strictly even inputs
  • Enforce strictly even outputs

Under "Prioritization" each port can be prioritized and it also displays whether it's an input or output port. It is possible to prioritize none, one, two, ... , or even all of the ports simultaneously, depending on the desired use case.

On the right side of the UI is "Priority", which sets the power/manpower/maintenance priority for this building. It is advised to keep this fairly high for any of the balancers, as they will severely damage any resource chains when out of order and they do not actually consume any manpower or maintenance, only 20 kW (Quantity, Flat balancer: 20 kW; from the game files, version 0.8.8d) of power.

Strictly Even inputs or outputs 

If both the first and the second toggles are activated, the transport will only pull equally from connected input ports and push equally to connected output ports, effectively acting as an (double) AND Gate.

Which means that if one of the output ports is full (blocked) then any resources won't be sent through any other output ports either.

Similarly when an input port is lacking resources, no resources are brought in from any other input ports.

Enforcing strictly even inputs/outputs resets any priorities set for the ports.

Priority input or output 

Any prioritized port is prioritized over a nonprioritized port. All nonprioritized ports are equal, all prioritized ports are equal.

Example use cases 

  • Priority input: to ensure that a Unit storage is emptied before accepting stock from a main conveyor line
  • Priority output: to ensure that Impure copper goes to a Copper electrolysis using Acid before falling back to one using Water
  • Balancing inputs: to ensure that two production lines of the same item are utilized equally to prevent backups of either one
  • Balancing outputs: to ensure that Cement from a Rotary Kiln is equally split between four Concrete Mixers